Supposing the cabin temperature is set to 75 degrees. Hi, our Truma Cp plus is now only showing the clock and the tool bar. Everyone loves a hot meal and a comfortable bed, but heating and hot water are two luxuries that really set tent camping apart from the RV. At least a hard fault should be easier to diagnose than an intermittent one.. Hopefully a final update for anyone who might come across this thread in the future. With kind regards If there is any water in the 2.6-gallon water container, the water will be heated automatically as well. They are about 35 each! I have a propane bottle but that means taking out the gas-it system . The gas pressure is normal and the boiler will operate with all the cooker burners lit as well as the fridge. Thanks, but already seen that. Especially when folks in Canada, Australia and the UK can buy the kit. -Service Centre-. Not all RVs need to use this featureours includedbut its important to know how it works and that its there in case you need it. Note: In our installation instructions, we recommend installing our units on permanent plus.This means that the power supply to our units cannot be switched off by the central control element (main panel). Clear editor. From the Truma Combi CP Plus control panel. Hi Pete, I can give you some insight of the low temperature capability of the Truma. We really like the Trumas variety of operations. This error refers to lack of gas and can be involked either by running out or starting up an application such as hot water with gas as the power source but with a bottle turned off. Thereafter, the electrical input takes precedence over propane. Indeed, a quick look at any RV equipped with these two archaic appliances and youll notice that they take up a lot of space. Started Sunday at 09:33 PM, By If you have an account, sign in now to post with your account. If this connection is interrupted, the control panel responds with the message W255H. Aventa roof-mounted air conditioning. GB 638 3492 15. -Service Center-. No leds are lightning or flashing at the circuit board. For a better experience, please enable JavaScript in your browser before proceeding. as were in Mallorca and I cant find a service agent here, as far as I can see. When operating the water heater, the power consumption is even less at .9 amps. Many thanks They will provide you the fix in this short video! Unfortunately, there is no trained service partner in Mallorca. The boiler will then go into standby mode and the fault code should be cleared. %%EOF The issue has been confirmed that the error happens when the system shuts down when the set temperature has been reached, so instead of going on stand by until the boiler needs to restart to maintain set temperature it thinks the gas supply has been lost and gives the error code. The wall cowl and the furnace are connected by an ingenious duct in the exhaust venting system, which consists of an exhaust tube inside and a combustion air intake tube outside. 2023 - Truma Gertetechnik GmbH & Co. KG Putzbrunn, Operating and Installation Instructions of the Truma CP plus, Truma heaters for caravans and motor homes, Your career with Truma Gertetechnik GmbH, Switch heater off and allow to cool. Will require a small transformer to boost power. Ill add a con to the list. Truma gas filling level display. Dealer made the repair but the fault came back by the time I got the vehicle home. My rig had four supply outlets and did a pretty good job of spreading the heat around, as far as compared to the furnance in my old Lance 815 this Truma is light years ahead. M~IrX9'67"FfU2p]34M. -Service Center-, Hi again, I can take of the control panel and send it for checking or replacement? CBG04EU-E-31209300 The Aventa gives RV [read more], Having an appliance fail during an outing is bad, its even worse when youre full-timing it in cold weather. Amanda, Hello Amanda, Also make sure that the TIN cable is firmly connected to the socket on the circuit board and also to the control panel. Existing users click here to access your account, Winter trip through France to Spain the result. Ah right. Can't predict when it's going to happen, but when it does it's always as the boiler's firing up. Just wondered as I had this issue. Please check whether the plug of the TIN cable is correctly seated in the socket on both the control element and the control board of the heater. -Service Center-, Hi again, unfortunately this hasnt resolved the problem. Blue Knight was on the money. Where can I purchase the truma Combi Comfort Plus for me to install it? With hindsight, I distinctly recall Truma technicians employing this term when talking amongst themselves about Combi problems. I now *think* that the second, two-stage regulator is bad. Truma Cooler BatteryPack. Hello! DickB Thanks again Spike, Hello Spike, If you figure out how to replace the key barrel let me know please! Truma gas lights. Upload or insert images from URL. Truma North America will be showing off their newest product at Tampas Florida RV SuperShow. When a PCB fails and the Magic Fairy becomes uncontrollable, the unpredictable consequences are referred to as "Puck Ups". Subscribers do not see these advertisements, To join in you must be a member of MotorhomeFun. 234 0 obj <>/Filter/FlateDecode/ID[<35ED2D0D3333F347BDE8F0CE844DCE59>]/Index[218 26]/Info 217 0 R/Length 82/Prev 26648/Root 219 0 R/Size 244/Type/XRef/W[1 2 1]>>stream I suspect that, if Truma bench-tested your Combi, they'd start by trying it on a known gas bottle/regulator system and - if the fault still showed up - replace the PCB, as neither of those approaches would involve opening up the appliance. it seems that your heater is not connected or the 12V power supply is interrupted. Kreis company started with a simple gas lamp, but today his company has grown into the leading caravan/RV component supplier in Europe. Truma Combi Fault Codes 2018 | TMC Leisure Apr. Kind regards, Either the E202H fault is genuine and theres some sort of gas-flow problem, or its spurious which might mean a PCB fault. Pour info, dans le pass, j'avois eu un code E 122 car le reservoir tait sur la rserve. Hello Paul, Without a problem. We love the Truma Combis small footprint and versatility and believe that it, along with similar products like the Alde hydronic water heater-furnacealso owned by Trumawill pretty much be standard in most recreational vehicles within 10 years. Then try resetting the control panel again. Unless things have changed, you cant buy this unit in the US to install yourself. Detailed information about the fault codes, their cause and how to fix them can be found in theOperating and Installation Instructions of the Truma CP plus. Time to get outside! hr6d: 3H>7>5r4/` XSLBPr&iX!b R. Newer units are also iNet ready, meaning that the unit can be controlled via Bluetooth/SMS with the addition of the iNet box and required smartphone application. I can also give you the correct article number for the circuit board. Weve been living in our truck camper rig for seven weeks now and its been quite [read more], Jack and Darcie Peeler are avid truck camper enthusiasts with a love for the outdoors. Then fill the fuel line as described in Initial startup (see Combi Diesel operating instructions). As youd expect for a high-tech item, the Truma Combi Eco Plus costs more than your typical American furnace and water heater with an $1,800 cost. https://www.truma.com/uk/en/service/customer-service, (It could help to know the age of your motorhome, when you obtained it and when this problem first showed up. Also make sure, that the heater is connected to 12V. Tried switching everything off and it made no difference at all. Two Trucks and Two Campers! 37 APPENDIX A - Error Codes If the appliance malfunctions, LED 2 (refer to "Overview / Designation of parts" on page 2) will flash to indicate the malfunction. Subscribers do not see these advertisements, To join in you must be a member of MotorhomeFun. If this connection is interrupted, the control panel responds with the message W255H.Please check whether the plug of the TIN cable is correctly seated in the socket on both the control element and the control board of the heater. Truma will only sell it to companies as OEM. You are using an out of date browser. The Truma Combi Eco Plus allows for the selection of three sources of power: Propane (gas), Electric (110 volts AC), and Mixed (propane and electric). Just wondered as I had this issue. Its been our experience that the water heater portion of the Combi heats water quickly and very efficientlywe usually have hot water within 20 minutes and when we say hot, we mean HOT. As youd expect for such a complex piece of engineering, there is a learning curve associated with the Truma Combi. brnd new heater/display on a caravan that hasnt even left the yard now in new zealand (hell hole of the south pacific) Direct processing through us is not possible. - I think you may need a special key as far as I can tell. Then reset the control panel again (Setup Reset PR Set Init) endstream endobj startxref So we can make sure, that the 12V power supply is enough. By Im happy to replace the pcb if you think its still the problem? we also had contact via email. Thanks. If the reset doesnt work, please contact one of our servicepartners: https://www.truma.com/int/en/truma-dealers This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register. Hello and welcome to our new forums! -Service Center-. Hello John, IOg4 I have a Combi 6 from 2018 in a Hobby autocamper Water temperature exceeded in winter mode: Switch off appliance and allow it to cool down. GB 638 3492 15. Do you have any suggestions? The article control panel cable coupling can be ordered from our specialist dealer (part number 39050-00175). Thanks Spike, Hello Spike, Magdalena Any ideas please to get us back running ? Mello Mike is an Amazon.com associate. kind regards, when a gas tap or bottle is shut or not fully turned on, or a regulator is partially blocked or frozen) thats what those discussions tend to concentrate on, with several comments mentioning advice from Truma that prolonged use of autogas (presumably when the leisure-vehicles gas system is not fitted with a Truma filter) can eventually provoke this error code. This can occur when the GAS bottle are switched off and you have selected the GAS as a. I have reseted the panel and after finished, I only see in the pannel de icons of de watch and the configurations key. Hello Remus, Check for obstructions such as slush, ice or leaves and remove from the openings. c HT, b|PCmF3n'Bm60S ifplC~` z Kind regards the electric icon only appears if an electric Truma device is installed. JavaScript is disabled. Thats a pretty significant savings in weight, especially in todays truck camper where every pound matters. Storage box air conditioning systems Saphir. E21H is listed in the manual as "Room temperature sensor or cable faulty". 0 After the reset the screen flashes a few times and returns to the clock. In this mode, the burner will switch off as soon as the water reaches the temperature selected on the control panel. If this is not defective either, I think the circuit board needs to be replaced. W255 H Have you tried contacting Truma direct? Got the same code and stove behavior. Wiring it in this manner allows us to use the Truma in the Mixed 1 mode in an emergency if the propane ever runs out while off-grid. You can only say for sure if the component is checked by a trained specialist workshop. I have a Truma CP Plus in my 2022 Thor Tellaro. The combi boiler isnt showing 12volt at the boiler ? The E202H error code does not seem to be that rare, but there appears to be no single simple certain cure. This is a review of the Truma Combi Eco Plus model, which runs on both propane and 110 volts AC. As for propane consumption, we dont have any measurements to say that the Truma Combi is better than the typical American water heater and furnace. Do you have a none refillable cylinder of Propane (eg Calor) to try to eliminate the gas supply side of things? Please check if the power supply and the TIN connection are given. - KK7TCA. 243 0 obj <>stream The 8th part of our video series for operating the. In the furnace mode, the Truma Combi has an adjustable temperature range between 40 and 86 degrees F. The furnace automatically selects the proper operating level based on the difference between the temperature set at the control panel and the current room temperature. After purchasing a Class B RV Coachmen Beyond 22C Alice and Tommy T expierienced a Truma Heater Furnance Hot Water System Error Fault E2 12 H. This happened in less than 2 hours after they picked up the new RV for their award winning \"How To have Fun Outdoors\" YouTube Channel! As soon as the cause is eliminated, the warning message disappears automatically from the display. https://www.motorhomefun.co.uk/forum/threads/truma-combi-error-codes.126354/, https://www.truma.com/uk/en/faq/fault-code-on-truma-cp-plus-control-panel.html. Presumably youve done the obvious amd GOOGLE-searched on combi error code e202h ? If youve ever had to replace a corroded anode rod in a Surburban water heater, youll really appreciate this feature. You cannot paste images directly. I'm getting an error code on my Truma display, E121H or E212H when I try to run the heating on gas. Thanks Spike, Hey Spike, Copyright Warners Group Publications Plc. Please contact your dealer for any complaints or part replacements. Ah, the comforts of the recreational vehicle. How do you find the interior furnace noise and balance of the heat throughout the cabin, given three heat outlets, particularly compared to a tradition furnace like in your Laredo? First, the dual capable unit takes up half the space since only one appliance is needed rather than two. Is this a fault with the PCB in the boiler? In 2013, Truma opened an office in Elkhart, Indiana in order to handle distribution and technical support here in the growing North American market. The motorhome is 2017, we have had a gas-it system for 4 years. 2022 Winnebago Travato 59KL 2017.5 Winnebago Travato 59K 2008 Sportsmobile Sprinter If this is not the case, the control panel responds with the message W255H.Please check the heating fuse in your electrical block as well as the fuse on the control board of the heating (Combi) or in the supply line (Varioheat). If necessary replace old battery, Lack of fuel due to insufficient fuel tank filling, tank has run empty and / or vehicle is on a slope. )https://www.youtube.com/channel/UCfUABeKVh7oJzZG93O2ZioQ/playlists\"How to have Fun Outdoors\" YouTube Channel is focused on Outdoor Activities, Outdoor recreation, Adventures and Reviews of amusement parks, campgrounds, and resorts. He currently rolls in a 4WD Ram 3500 outfitted with a SherpTek truck bed with a Bundutec Roadrunner mounted on top. endstream endobj 219 0 obj <>/Metadata 4 0 R/Pages 216 0 R/StructTreeRoot 8 0 R/Type/Catalog>> endobj 220 0 obj <>/Font<>/ProcSet[/PDF/Text]>>/Rotate 0/StructParents 0/TrimBox[0.0 0.0 612.0 792.0]/Type/Page>> endobj 221 0 obj <>stream This versatile little unit not only can heat the air and water in your RV, but can do so with greater efficiency. Thanks for your comments. Kind regards, In addition, we will be sharing great videos on roller coasters and amusement parks like Disney, Bush Gardens, Cedar point, and many others. Turn the stove on and light it until it keeps burning. Truma wont sell it they only supply to new campers to be build in as the first heating systems. In the Mixed Mode, propane is used until the desired temperature(s) is/are reached. As for the furnace portion of the Truma Combi, weve been somewhat disappointed. My contact added that all the MFs are called Puck and the PCBs fitted to Combis are actually "Puck Control Boards". Our goal is simple! I think there is a company in Canada that will sell you one, but I dont think it is supported by Truma. Faulty gas regulation seems to be the only likely pick from their list of causes, but I will check for the others again. Does anybody know? hr6d: 3H>7>5r4/` XSLBPr&iX!b R. Some of the add-ons on this site are powered by. Rather than wiring the AC side to the main AC breaker box, we have our Truma wired to the output of our 3,000 watt inverter, which has a built-in transfer relay. kind regards -Service Center-, Hello Kevin, Powered by Invision Community. I cant get one. According to the operating manual, the hot water mode is ideal only if hot water is required. Additional error codes that the owner should be aware of include an empty water tank (E17H) and loss of 12 volt DC power (E255H). All rights reserved. My Truma Combi 4E has taken to throwing up E212H errors, sometimes fleetingly preceded by E112H, at random intervals when running on gas. truma cp plus display. Air in the line. please check if the tin cable between the heater and the control panel is plugged in correctly. Daniel. It also allows us to operate the Truma on shore power normally. The consumption rate depends on so many things including ambient temperatures, the campers R-rating, and other variables which are difficult to quantify, but with the Truma Combis quick hot water heating cycle and lower 14,300 BTU rating, it certainly seems that the Truma uses less propane compared to other campers weve owned. You are using an out of date browser. You're An RVer Now, And You Just Realized Health I See The Before & After Of This Fifth Wheel RV Headboard Ideas To Spruce Up Your Space, See Inside This Renovated 1983 Scamp Trailer, Disney's Fort Wilderness Resort & Campground, Rainbow Plantation - Escapees Rainbow Park, What To Do If Your RV Breaker Keeps Tripping, RV Safe Turn By Turn Directions on Your Phone, https://www.truma.com/uk/en/faq/faulrol-panel.html. HWH}WN[} B`g,aK]2TKAtTv)\,A. Weve also discovered that the furnace portion of the Truma Combi is a bit temperamental when running on propane. The unit consists of a burner tube in the middle, which is about the size and shape of a Pringles potato chip can, an aluminum heater exchanger wrapped around the burner, and a 2.6-gallon stainless steel water tank encased around the heat exchanger.