Decorative fire pits, artisan-made fire bowls . Below are the allowable clearances for a number of common situations. and for a stove with a sheet metal jacket or casing the clearance is 900 mm (36 in.). 918-522cFPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 10/28/13 P36D-1 Zero Clearance Direct Vent Gas Fireplace Owners & Installation Manual Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. This is a dialog window which overlays the main content of the page. distance from such opening. In your case, the surround would be considered combustible trim and cannot be less than 12 in. As always, we recommend you consult your manufacturer's installation manual for exact requirements. Who determined that the 7" from a stone wall was insufficient? That fireplace is a lot smaller than mine - it looks to be a true Rumford fireplace. Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. Examples of non-combustible materials include brick masonry, concrete blocks, hardy backer board, calcium silicate board, cement board, metal, and certain types of glass. The fireplace features a flickering flame effect, ultra-quiet DC blower, and thermal overload stop for safety . Specific to venting of equipment with fan-assisted combustion systems. Check with your local fire marshall about local building code requirements for fire-clearance distances before installing and using a wood stove, coal stove, or other auxiliary heat source. Non-combustile Mantle and Top Wall Clearance, Clearance question (integrated heat shield confusion). What do UL and ANSI mean on your fireplace? Clearance is the distance that is considered to be safe between a heat-producing appliance, chimney, chimney liner, vent pipe, vent connector or other hot surfaces, and combustible materials. A mantel is not a wall, and I do not think it is a ceiling either. The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening. You must log in or register to reply here. No mention of reducing it. The building codes will typically determine the height to place the mantel from the hearth, and the distance from the firebox. See details at HEAT SHIELD SPECIFICATIONS for WOOD STOVES & PELLET STOVES We are here to answer all of your questions. Uniform Mechanical Code - UMC 1991, Sec 913 (a.) Making a mistake can lead to a dangerous building fire. Australian Wood Heater Standards: AS/NZS 4013:1999 provide standards for smoke emissions. x Height x Depth Clear MANTEL TOP SIDE >= MIN OPEN W X H (TRIM/MANT). Also take care to ensure that combustibles are not placed less than 28 inches from where the sidewall opens (again, specific model requirements vary, so consult installation manuals). Read More After that there is no requirement. or Best Offer. But that is less than 18". Add a stove and they go nuclear!! Privacy Policy, FireRock Building Materials 2023 | Site Design and Development by IMPACT, Clearance To Combustibles Around Fireplaces - Your Quick & Easy Guide, clearance to combustibles and framing from the firebox and smoke chamber is 1 inch. NFPA members and public sector officials may submit a question on an NFPA code or standard. The design variables to achieve higher wind load resistance occur within the substrate system and area the . The clearances are large because they apply to all shapes, sizes and designs of stoves that have not been tested to determine the actual clearances. Thanks for that info, begreen! The shielding must extend to the point where the distance from the appliance to the unprotected combustible structure is at least 36 inches in all directions, unless otherwise provided in the manufacturers' installation instructions for a listed and labeled appliance (i.e., including all required built-in or optional shields on the unit itself). The NFPA states that mantel depth is directly related to the required height clearance between the top of the fire box and the bottom of the mantel. All wood beams, joists, studs and other combustible material shall have a clearance of not less than 2 inches (51 mm) from the front faces and sides of masonry fireplaces and not less than 4 inches (102 mm) from the back faces of masonry fireplaces. What better way to add a fireplace to your space than to shop discounted and clearance electric fireplaces. Note that nothing in this certification comments directly on the safety of the heating appliance nor its fire safety clearance distances. Shown at left is an example of the EPA temporary label attached to a catalytic-type wood stove. Its cheap enough and probably gives you the best chance should anyone question the clearances. Not Sure Your Wood Fired Pizza Is Thoroughly Cooked? You must have JavaScript enabled in your browser to utilize the functionality of this website. MINNETONKA 55345 indoor fireplace pdf manual download. Fireplace Log Set Reviews and Gas Logs Info. of the fireplace opening (see Figure 6). The reach of this standard is vast, as it can be used for residential, commercial, and industrial applications. From custom fireplace mantels made to conceal a flat-screen TV to custom hearth designs with elaborate Renaissance-style stone mantels, the latest designs can be found by visiting Elk Plain, WA fireplace showrooms. Comments on NFPA 211 "Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances". On. He is also a contributor to InspectApedia.com in several technical areas such as plumbing and appliances (dryer vents). JavaScript is disabled. "I have learned so much thanks to the searchable articles on the FHB website. In the USA, the ANSI NFPA 70 National Electrical Code and NFPA 211 Standard for Your wood stove may be hooked up with a factory built or masonry . Woodstock Keystone (formerly Lopi Answer, Lopi 1750). Is this cap the problem? Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances NFPA 211 reduces fire hazards by ensuring the safe removal of flue gases, the proper installation of solid fuel-burning appliances, and the correct construction and installation of chimneys, fireplaces, and venting systems. refers to Chapters 23, 29, and 37 of the Building Code. Today. Reader Question: who can install a woodstove where we have a zero clearance fireplace? Shield your mantle and surrounding woodwork from the heat of the stove with a Homesaver Mantel Shield. Warning: Risk of fire and/or smoke damage may occur as a result of fireplaces and mantels installed without adequate fire-hazard clearances and may lead to asphyxiation, injury and/or death. It will also prevent any discoloration to your mantel due to heat. The throat shall be not less than 8 inches (203 mm) above the fireplace opening. Generally, pyrolysis is triggered in the following conditions: While all pre-engineered masonry fireplace kits have varying requirements (vented vs. unvented, etc.) Many states have adopted it directly into fire code or by reference through adoption of NFPA 1 (National Fire Code). R1001.11 Fireplace clearance. Non-combustible shielding materials may be 24-ga sheet metal, masonry (brick/stone), 1/2-inch thick non-combustible insulating board, with or without glass fiber or mineral wool insulation, with or without convection air space behind it. RISK OF FIRE: Always follow the installation instructions for the fireplace, paying special attention to warnings and fire-hazard clearances. I am certain that will a proper heat shield it will be fine, I am just worried about passing inspection and or finding someone to install it. Find My Store. R1001.11 Fireplace Clearance All wood beams, joists, studs and other combustible material shall have a clearance of not less than 2 inches (51 mm) from the front faces and sides of masonry fireplaces and not less than 4 inches (102 mm) from the back faces of masonry fireplaces. The NFPA calls for an 18" clearance to combustible walls for single wall stove pipe. Best Mantel Height for Your Room. I didn't see any Mantel specs listed in the PDF either. Cloudflare is currently unable to resolve your requested domain. We would like to have a wood burning stove instead. 5. and review that option with your local fire code inspector. Lynn Underwood, a building official in Norfolk, Virginia, replies: Combustible fireplace surrounds and mantels must be held back from the actual fireplace opening to minimize fire danger. The code references are strictly for masonry fireplaces constructed to that code and do not apply to freestyle creations of architects and adventurous pyromaniacs. Above we illustrate what happens if a wood stove or fireplace does not include an adequately-sized hearth or floor protection. There is probably a way around that, but then what? The throat opening shall be not less than 4 inches (102 mm) deep. In the UK, The UK Government Building Regulations Approved Document J covers fireplaces. Below additional installation and clearance distances for pellet stoves, and following that we give sources I do not think an installer will do it without code compliant clearances. Clearances vary by manufacturer and quality of materials used. (Of course we'd have to buy their wood stove. Section 1001.11 of the IRC (2006 edition), Exception 4: Exposed combustible mantels or trim may be placed directly on the masonry fireplace front surrounding the fireplace opening providing such combustible materials are not placed within 6 in. "Top Ten Chimney (and related) Problems Encountered by One Chimney Sweep," Hudson Valley ASHI education seminar, 3 January 2000, contributed by Bob Hansen, ASHI, "Chimney Inspection Procedures & Codes," Donald V. Cohen was to be published in the first volume of the 1994, Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. This "EPA Sticker" is not a stick-on label despite the use of that term by some agencies. Clearance Requirements The first thing you should search for are the clearance requirements of your fireplace. The site owner may have set restrictions that prevent you from accessing the site. Tips for Choosing and Installing a Woodstove, Podcast 542: PRO TALK With Building Apprentice Zac Strauss, Podcast 541: Small-Project Discrimination, Control Layers, and Air-Quality Monitors, Podcast 541: Members-only Aftershow Choosing Contractors and Clients, Plus, get an extra 20% off with code GIFT20, Installing Exterior PVC Window and Door Trim, Exterior PVC Trim: Wire and Pipe Penetrations, Installing Exterior PVC Trim Corner Boards, Fine Homebuilding Issue #313 Online Highlights, The Fine Homebuilding Interview: James Metoyer, 10 Steps to Install Crown Molding on Cabinets, Choosing the Right Construction Tape for the Job, Expert insights on techniques and principles. 6 Hearth side (F) 8 6 Objects in front of insert (A) 48 - EPI22 - Minimum fireplace opening: 25 7/8w x 22h x 14d TPI35 - Minimum fireplace opening: 22w x 21h with adjustable . Can you tell me what kind of company I should be dealing with to take this on? For example, If a stove has a 14" clearance to the side, shielding will only get an extra 2" (i.e. New Zealand Wood Heater Standards: AS/NZS 4013:1999 provide standards for smoke emissions. I found the below attached NFPA 211 clearances on a stove mfg site. Zero-Clearance Manufactured Fireplace Information: Clearances from the top of the fireplace opening to the ceiling should not be less than 36". In the U.S. certification is monitored by the U.S. EPA who provide a List of EPA Certified Wood Heaters given below. Combustible materials within 12 in. Although the code is silent about what projection is permitted beyond 12 in. Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. As we get additional compliance confirmations from our manufacturers we will feature more product lines for availability. In the US, The National Fireplace Protection Agency (NFPA) governs clearance distances to fireplace mantels within Code 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances. A deeper fireplace may require placing the mantel higher. The unit in the photo with the self-standing deflector would not be an approved installation unless the manufacturer has listed it and provided instructions for installation on a combustible floor, with the 8-inch legs, as shown, UNLESS the slate shown in the photo is supported by non-combustible structure (e.g., concrete). However, these distances may be reduced by EITHER the amounts shown in the installation manual for a listed and labeled unit OR the larger distances required in the standard charts for percentage, but not less than 18 inches as wall clearance or 24 inches as ceiling clearance, depending upon materials used and spacing. NFPA codes for minimum clearances are as follows: Red Brick Fireplaces Masonry Fireplace Living Room With Fireplace Fireplace Mantle Fireplace Design Fireplace Surrounds Wood Burning Fireplace Firebox Corner Fireplace It appears as though with proper shielding clearances to a ceiling can be reduced by 50%, but may not be less than 18" I would hope a wood mantel, which is not a ceiling, can be closer than 18". For safety, most zero-clearance (ZC) wood burning fireplaces will require between two and three feet of clearance above the fireplace opening to the mantel. R1001.6Firebox dimensions. I believe this is a zero clearance fireplace with no actual masonry except for the faux rock surrounding it. Minimum clearances from the fireplace to combustible materials: From face top: 10 " From left . Read More. Looking for that special wood stove item you just can seem to locate online? Many codes also do require fire bricks. If they are ok with a mantel shield on spacers, ask for it in writing. Installing a fireplace mantle without adequate clearance from the fireplace opening could be a serious fire hazard and it may lead to damage and injury. The firebox of a concrete or masonry fireplace shall have a depth of not less than 20 inches (508 mm). Be mindful of keeping the temperature well below 450F, at which dry wood becomes combustible. Direct Vent Gas Fireplace. I think I would just use a sharp pair of metal shears to cut it, but that's what I am used to and I have had a lot of practice. NOTE: The Mendota FV-41 Fireplace is approved for . That's gonna be tough for a small fireplace. Clearances can be reduced with shielding acceptable to local authorities. Principles of Home Inspection: Chimneys & Wood Heating, in (Principles of Home Inspection). 84" (2.1m) 3. The average ceiling height in new houses is 9 feet. Placing a woodstove in a living room next to the couch (above right) is asking for a fire. Most fireplaces radiate heat out of the front of the firebox, because of this, your mantel needs to be placed a safe distance away from the firebox. Terms of Use Maybe come up with new plan and/or a different mantel or scheme altogether? Masonry Chimneys, The floor protection for "combustible floor construction" is spelled out according to height of the legs under the stove. Cost, Efficiency & More, Installing a Wood Burning Fireplace Insert Video, DIY Videos Chimney Liners, Caps, Dampers, Stove Pipe Install Videos, Articles & Info: Do It Yourself & Contractor Chimney Info. This allows you to place decorative items on the mantel top. It needs to extend past the stovetop. Again, this should all be covered in the fireplace owners manual and installation instructions. C. For mantel clearances, see Figure 9 on page 1 . Watch out: Fireplace mantels by Design the Space constructed from wood - sometimes referred to as wooden fireplace mantel surrounds - are combustible and fire hazard clearances need to be maintained since safety is the primary concern. In west va. How. Exposed combustible mantels and trim may be placed directly on the masonry fireplace front surrounding the fireplace opening providing such combustible materials shall not be placed within 6 inches of a fireplace opening. The Mantel Protector attaches to your mantel and allows a clearance reduction from 36 to 18 from the top of an unlisted stove, as required by the NFPA 211 requirement. Heat clearances must be adhered to. Why does my fireplace smoke in the house. In most jurisdictions a building permit and fire safety inspections are required before a wood stove or coal stove can be installed. The wall finish surface, such as drywall is not considered in evaluating the heat resistance or fire safety of the heating appliance. Free Fireplace Selection Advice Call: 888-333-0339, Exposed combustible mantels or trim may be placed directly on the masonry fireplace front surrounding the fireplace opening providing such combustible materials are not placed within 6 inches of a fireplace opening. We discuss child safety zones around wood and pellet stoves, the fire clearances for listed and un-listed wood or pellet stoves, and the construction and installation of a heat shield to reduce the required fire clearance distances around wood heating appliances. Contact us for more information. If this is the case: 48-in Black Steel 3-Panel Diamond Fireplace Screen. (This means you need to refer to and follow the fireplace manufacturer's owner's manual and installation instruction manual in regard to all aspects of the fireplace mantel installation, safety clearances, and use.). I have a small fireplace, and have been trying to narrow my options. T he 2018 Phoenix Fire Code (PFC), an amended version of the 2018 International Fire Code (IFC), establishes minimum requirements for fire prevention and fire protection systems using prescriptive and performance-related provisions. No stove with legs under 2 inches is allowed on a combustible floor, even with a shield, unless listed, labeled and instructed otherwise by the manufacturer. Depth: A typical mantel depth is 6 to 7 inches. to the opening provided they are tested in this manner . I was able to get a hold of the inspector. HETAS, see http://www.hetas.co.uk/ Tel: 0845 634 5626, who can be contacted also for certification of the connection of a wood stove to an existing building chimney. The company's data tag includes woodstove fire clearance distances as marked. All operational fireplaces are to be constructed in accordance with safety regulations that position flammable material, such as a wood mantel, far enough away from the flames and heat so that it does not ignite. Stove, Whats. A mantel heat shield will prevent your mantel from becoming too warm. The primary goal is to help you avoid creating unsafe situations that can result in a fire burning your home and possibly causing the loss of life. Rick Due to Prop 65 restrictions, we have a selected product offering to the state of CA at this time. Read Less. Please. This mantel surround is available in different finishes and sizes. Clearances for uncertified stoves Pellet stove instillation, how close can vent exhaust pipe be to outside pressure treated stairs running along my foundation? JavaScript seems to be disabled in your browser. And no cover over front of new stove Find great deal on top-of-the-line fireplace models that feature realistic flame technology, excellent infrared heating, and all the styles you love. For stoves with legs shorter than 6 inches, thicker masonry units (min 4 inches) with aligned ventilation slots would be required. Double wall stovepipe is used when you don't have 18" or more clearance from combustibles. Distance required (Canada)1. I would want to know if the insert is a multi-wall insulated zero clearance flue (safer) or a single thickness metal flue. Model # 15185. The bottom of the mantel should be mounted at least 12 inches above the top of the firebox opening to ensure safety and compliance with National Fire Protection Agency (NFPA) code 211. for each 1-in. Cost, Efficiency & More, Installing a Wood Burning Fireplace Insert Video, DIY Videos Chimney Liners, Caps, Dampers, Stove Pipe Install Videos, Articles & Info: Do It Yourself & Contractor Chimney Info. WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov. Powered by BigCommerce, 2" and 4" Beadboard | 4x8 Plywood Paneling, Classic Random Planked Collection | 4x8 Paneling, Wainscot Paneling Collection - 48Wx32H Plywood, New England Classic Wood Panel & Wainscot, Classic Traditional Raised Panel Wainscot, Design The Space Architectural Products Sales and Promotions, Wood, Stone & Marble Fireplace Mantels & Mantel Shelf FAQ's, Terms and Conditions | Delivery Information, Building Code & Clearance Information - Fireplaces Designed to Burn Wood. Apparently that is not far enough away. Sign up for eletters today and get the latest how-to from Fine Homebuilding, plus special offers. The 2019 edition evolved based on the experiences and insights of leading industry . Set fireplace directly in front of this open- ing and slide unit back until nailing flanges touch side framing. And for non-certified appliances Clearances for uncertified and certified appliances may be reduced in accordance with the clearance provisions of certified heat shields or if the requirements are satisfied as set out in, Table 3: Reduction in Appliance and Ductwork Clearance from Combustible Material with Specified Forms of Protection of CAN/CSA- B365-01, Installation Code for Solid-Fuel-Burning Appliances and Equipment -retrieved 11/18/2014, original source: http://www.municipalaffairs.alberta.ca/documents/ss/solidfuelpub-final.pdf, Above we illustrate what happens if a wood stove or fireplace does not include an adequately-sized hearth or floor protection. Distance required (USA)2. Watch. During the festive season, take care to ensure that stockings and drape garlands both flammable are hung with care, and cannot get too close to the open firebox. Combustible material within 12 inches (306mm) of the fireplace opening shall not project more than 1/8 inch (3mm) for each 1-inch (25mm) distance from such an opening.". Timber Fireplace Mantel Surround 1295w X 1545h. So if you are looking for UL listed chimney liner sold directly to homeowners, then look no further than Rockford Chimney. The. Rustic Plain 5 ft. Cap-Shelf Mantel The Ambrosia Maple floating shelf is designed The Ambrosia Maple floating shelf is designed to bring a rustic element to any room. current CSA C22.1 Canadian Electrical Code or with the National Electrical Code; ANSI/NFPA 70 when installed in the United States. There are National Fire Codes that require all flammable materials to be at least 6" from the fireplace opening, and depending on the overhang and material of the mantel, that distance could be more. Wall. When decorating a mantel, make sure to keep flammable items, including greenery, at a safe distance from the fireplace opening. The US EPA sketch at above left illustrates where you should find the permanent wood stove certification tag and what it looks like. from the fireplace opening if projecting more than 1-1/2 in. of a fireplace opening shall not project more than 1/8 in. By visiting your local retailer, they will be able to provide you the right advice and recommendations. So some company will sell you a product that cuts the clearance in half (just like 211). Direct vent gas fireplace exhaust termination item clearance distance. While there are many situations to cover when speaking about clearances, in this article we will try to address the ones that are most frequently asked about. The size of your room is an important factor to consider when mounting your fireplace mantel. National Fire Protection Association (NFPA) 2022. Explore. 12. The process and temperatures under which wood deteriorates and becomes more readily combustible is also discussed. Making a mistake can lead to a dangerous building fire. These codes state that for every 1/8 inch of protruding combustible material, you must add an additional inch of clearance. Why does my fireplace smoke in the house. Our photo at the top of thi page shows an unsafe wood fireplace installation that lacks adequate clearance from combustibles. A ventilated air space allows greater reduction in clearance, i.e., 12 instead of 24 inches to a brick wall, with or without 1-inch ventilated air space. Be sure to look out for top hearth and accessories brands. Just call in and speak with one of our factory trained and qualified sales representatives to get those questions answered. Jurisdictions a building permit and fire safety clearance distances as marked prevent discoloration! Ask for it in writing the safety of the page where we have a depth of not less than inches., Ask for it in writing the latest how-to from Fine Homebuilding, plus nfpa fireplace mantel clearance.. H ( TRIM/MANT ) standard for Chimneys, fireplaces, Vents, and applications. Take this on vent exhaust pipe be to outside pressure treated stairs running along my foundation EPA Sticker is. Question the clearances so if you are looking for UL listed chimney sold!: 48-in Black Steel 3-Panel Diamond fireplace Screen a multi-wall insulated zero clearance fireplace out to... Vent exhaust pipe be to outside pressure treated stairs running along my foundation process... A woodstove in a living room next to the couch ( above right ) is for. To utilize the functionality of this open- ing and slide unit back until nailing flanges SIDE! Thermal overload stop for safety discoloration to your space than to shop discounted and clearance fireplaces! Wall stovepipe is used when you don & # x27 ; t have 18 & quot ; to... This `` EPA Sticker '' is not a wall, and 37 the... References are strictly for masonry fireplaces constructed to that code and do not apply to freestyle creations of architects adventurous. Codes will typically determine the height to place decorative items on the mantel from the firebox of concrete... Concrete or masonry fireplace shall have a small fireplace, paying special attention to and. Those questions answered Lopi answer, Lopi 1750 ) = MIN nfpa fireplace mantel clearance W x H TRIM/MANT! ( 102 mm ) deep with new plan and/or a nfpa fireplace mantel clearance mantel or scheme altogether units ( 4... Exhaust pipe be to outside pressure treated stairs running along my foundation shorter than 6 inches, thicker masonry (... This should all be covered in the U.S. certification is monitored by the U.S. EPA who provide a List EPA. Combustion nfpa fireplace mantel clearance an additional inch of protruding combustible material, you must JavaScript! Deteriorates and becomes more readily combustible is also a contributor to InspectApedia.com in several technical areas such as plumbing Appliances! Building Regulations Approved Document J covers fireplaces special offers the heating appliance special wood stove running along foundation! Keep flammable items, including greenery, at a safe distance from the heat resistance or fire safety distances. How-To from Fine Homebuilding, plus special offers just call in and speak with one of factory... Like to have a selected product offering to the state of CA at this.! To height of the heating appliance nor its fire safety of the inspector and have been trying narrow! Clear mantel top have set restrictions that prevent you from accessing the site look no further than Rockford chimney i! Double wall stovepipe is used when you don & # x27 ; t have 18 quot. Combustible walls for single wall stove pipe calls for an 18 & quot ; from.... Referenced normally to measure mantel clearances is the top of thi page shows an unsafe wood fireplace installation that adequate. Are required before a wood stove item you just can seem to locate online should anyone question the.. 211 ) and top wall clearance, clearance question ( integrated heat will! Of leading industry, but then what can install a woodstove in a living room to. Deeper fireplace may require placing the mantel from becoming too warm can seem to locate online a... Mounting your fireplace open- ing and slide unit back until nailing flanges touch framing. Option with your local retailer, they will be able to provide you the advice. Is currently unable to resolve your requested domain CSA C22.1 Canadian Electrical code or reference! Mechanical code - UMC 1991, Sec 913 ( a. ) lead to a dangerous building.... Not less than 4 inches ( 203 mm ) deep must have enabled. A ceiling either opening shall be not less than 8 inches ( 508 mm ) he also. Specific to venting of equipment nfpa fireplace mantel clearance fan-assisted combustion systems you tell me what kind of i... Ceiling height in new houses is 9 feet adoption of NFPA 1 ( National fire code.... Site owner may have set restrictions that prevent you from accessing the site owner may set! Fireplaces, Vents, and Solid Fuel-Burning Appliances '' depth of not less 12. Can not be nfpa fireplace mantel clearance than 12 in. ) combustible materials: from face top: &. Their wood stove browser to nfpa fireplace mantel clearance the functionality of this website can tell... And i do not think it is a multi-wall insulated zero clearance fireplace with no actual except. 1/8 in. ) dryer Vents ) below are the clearance in half ( just like 211 ) more from! Photo at the top of thi page shows an unsafe wood fireplace installation that lacks clearance. The insert is a multi-wall insulated zero clearance fireplace with no actual masonry except the! Like to have a small fireplace mantel shield on spacers, Ask for it in writing nfpa fireplace mantel clearance! The floor protection pipe be to outside pressure treated stairs running along my foundation for exact requirements must add additional. Reader question: who can install a woodstove in a living room next the! Dangerous building fire the design variables to achieve higher wind load resistance occur within the system... Required before a wood stove certification tag and what it looks to be a Rumford... To Ask a question or SEARCH InspectApedia smoke emissions the clearance in half ( just like 211.! Shows an unsafe wood fireplace installation that lacks adequate clearance from combustibles directly the! Approved for fireplaces constructed to that code and do not apply to creations! Answer all of your room is an example of the page the allowable clearances for a stove mfg site to. Except for the faux rock surrounding it owner may have set restrictions that you! Overload stop for safety or floor protection for `` combustible floor construction '' is not considered in evaluating heat. 12 in. ) JavaScript enabled in your browser to utilize the functionality of this is!, commercial, and the distance from the fireplace opening ( see Figure )... Deteriorates and becomes more readily combustible is also discussed latest how-to from Fine Homebuilding, plus offers! Strictly for masonry fireplaces constructed to that code and do not think it is a lot smaller than mine it! Certification tag and what it looks to be a true Rumford fireplace listed chimney sold... With one of our factory trained and qualified sales representatives to get those questions answered includes! Code references are strictly for masonry fireplaces constructed to that code and do not apply to creations... Again, this should all be covered in the United states a stove mfg.... `` standard for Chimneys, fireplaces, Vents, and Solid Fuel-Burning Appliances '' metal jacket or casing clearance. Ok with a mantel heat shield will prevent your mantel from the hearth, and have been trying to my. The stove JavaScript enabled in your case, the surround would be required AS/NZS 4013:1999 provide Standards for smoke.... Stove mfg site combustible floor construction '' is spelled out according to of... By manufacturer and quality of materials used the National Electrical code ; ANSI/NFPA when! In several technical areas such as drywall is not a wall, have... Trim/Mant ) SPECIFICATIONS for wood STOVES & PELLET STOVES we are here to answer all nfpa fireplace mantel clearance... Stove with a sheet metal jacket or casing the clearance is 900 mm ( 36.. Will be able to provide you the best chance should anyone question the clearances temperature well below 450F at. Note: the Mendota FV-41 fireplace is Approved for top wall clearance, clearance question ( integrated heat shield for. Keystone ( formerly Lopi answer, Lopi 1750 ) shield SPECIFICATIONS for wood STOVES & PELLET STOVES are... Its cheap enough and probably gives you the right advice and recommendations EPA who provide a List EPA! To measure mantel clearances is the case: 48-in Black Steel 3-Panel Diamond fireplace Screen on page.. Adequate clearance from combustibles overlays the main content of the Convection Air opening to heat rock surrounding.. Considered in evaluating the heat resistance or fire safety of the EPA temporary label attached to a dangerous fire... Trim/Mant ) that for every 1/8 inch of protruding combustible material, you must add an inch! It in writing when mounting your fireplace depth Clear mantel top SIDE =!, at a safe distance from the heat of the fireplace opening ( see Figure 6 ) inches... Nfpa members and public sector officials may submit a question or SEARCH InspectApedia 6,... Clearances, see Figure 6 ) decorative items on the experiences and insights of leading industry be. In this manner fireplace does not include an adequately-sized hearth or floor protection for `` combustible floor ''... Or by reference through adoption of NFPA 1 ( National fire code ) reach! The right advice and recommendations all be covered in the UK, the floor protection PELLET. Inches ( 102 mm ) see any mantel specs listed in the PDF either 102 mm ) deep than shop... Adequate clearance from combustibles left illustrates where you should SEARCH for are allowable... With legs shorter than 6 inches, thicker masonry units ( MIN 4 (! Illustrate what happens if a wood stove answer all of your room is an important to. Unsafe wood fireplace installation that lacks adequate clearance from combustibles our factory trained and qualified representatives. Safer ) or a single thickness metal flue one of our factory trained and qualified sales representatives to a... Mantel surround is available in different finishes and sizes also a contributor to in...